Product Details:
Payment & Shipping Terms:
|
Phase: | Three Phase Input Single Phase Output | Input: | 380Vac |
---|---|---|---|
Output: | 220Vac | Frequency: | 50 / 60Hz |
Battery: | Lead Acid Battery | Capacity: | 10Kva , 15Kva , 20Kva |
Wave: | Pure Sine Wave | ||
Highlight: | online double conversion ups |
10-20Kva Three Phase Input Single Phase Output High Frequency Online UPS 380V / 220Vac
DSP Technology
Active input power factor correction (PFC)
Wide range of input voltage and frequency
Zero power switch delay
Active Load Management
Sufficient Expansion Slots
The load power factor is 0.8
Support the Generators: The wide range of input voltage and frequency can effectively separate the harmful electric wave produces by the generators and provide safe and reliable power supply.
Model# | 3CE10K | 3CE15K | 3CE20K | Comments |
Input | ||||
Input voltage | ||||
Rated voltage | 380VAC/220VAC | |||
Phase | three phase with ground | |||
Turn on voltage range | (120±5~274±5)VAC | |||
Bypass voltage range | (60±5~300±5)VAC | Could be adjusted by software. | ||
Bypass low loss | 60VAC~220VAC(default 60VAC) | |||
Bypass low comeback | Low loss +5VAC | |||
Bypass high loss | 220VAC~300VAC(default 300VAC) | |||
Bypass high comeback | High loss -5VAC | |||
Line low loss/comeback | (120±5) VAC /(140±5) VAC | load≤50% | ||
(150±5) VAC /(165±5) VAC | 50%<load≤80% | |||
(160±5) VAC /(180±5) VAC | load>80% | |||
Line high loss/comeback | (274±5)VAC/(260±5)VAC | |||
Input frequency | ||||
Rated frequency | 50Hz | |||
Frequency low loss | (40~49) ±0.2Hz(default:46Hz) | Could be adjusted by software. | ||
Frequency low comeback | Frequency low loss +0.5Hz | |||
Frequency high loss | (51~60)±0.2Hz(default:54Hz) | |||
Frequency high comeback | Frequency high loss -0.5Hz | |||
Input power factor | ||||
Input power factor | > 0.95 | 220VAC,full R load | ||
Generator | Support generator input | Generator rating≥2*UPS rating | ||
Input current | ||||
Rated current | 45A | 68A | 91A | |
Input THDI | <= 25% | |||
Output protection | ||||
Rating protection | 50A Breaker | 80A Breaker | 100A Breaker | |
Output power | ||||
VA/watt | 10KVA/8KW | 15KVA/12KW | 20KVA/16KW | |
Rated voltage | 220VAC | Sine wave | ||
Voltage range | 200/208/220/230/240VAC | Could be adjusted by software. 10% derating for 208VAC/200VAC. | ||
Voltage regulation | ±1% | |||
Voltage distortion | ≤6% | Full RCD load | ||
≤2% | Full R load | |||
DC offset | ≤200mV | |||
Transient response | ≤9% | R load 0%~100%~0% | ||
≤6% | R load 20%~100%~20% | |||
Transient recovery | ≤60ms voltage recovery to 90% | Full RCD load | ||
Bypass output before turn-on | YES | |||
Crest ration | 3:01 | |||
Output frequency range | ||||
Normal mode | 1,Same as input frequency(46Hz~54Hz) 2,50Hz(Input frequency>54Hz or Input frequency<46Hz) |
|||
Battery mode | (50+0.1) Hz | |||
Slew rate | 1 Hz/Sec | |||
Efficiency | ||||
Normal mode | > 90% | |||
Battery mode | > 88% | |||
Overload | ||||
Normal mode/battery mode | Overload warning only | 105%±5%≤load | ||
1min,then transfer to bypass and alarm. | 105%±5%<load≤125%±5% | |||
30S,then transfer to bypass and alarm. | 125%±5%<load≤135%±5% | |||
100mS, then transfer to bypass and alarm. | load>135%±5% | |||
Automatically retransfer | YES | |||
Short protection | ||||
Normal/battery mode | YES | |||
Transfer time | ||||
Normal to battery mode | 0mS | |||
Battery to normal mode | 0mS | |||
Normal to bypass mode | 0mS | |||
Bypass to normal mode | 0mS | |||
Battery and charger | ||||
Battery | ||||
Rated voltage | 192VDC | |||
Type/Rating | ||||
Battery quantity | 16 | |||
Backup time | ||||
Protection | ||||
Low alarm voltage / comeback voltage | (180.8V±4V)/ (188.8V±4V) | |||
Shutdown voltage/ comeback voltage | 160V±4V/168V±4V | 171.2V±4V/177.6±4V | Watt Value < 1000 | |
176V±4V/184V±4V | Watt Value >= 1000 | |||
DC protection | ||||
Overcharge protection/ comeback voltage | (249.6V±4V)/ (216V±4V) | |||
Leakage current | < 500uA | |||
Over discharge protection | 14.5h | Could be set by software | ||
Battery test | ||||
Battery weak | YES | |||
Battery fault | YES | |||
Charger | ||||
Output voltage | (219.2±3)VDC | |||
Charge time | Depends on the external battery capacity | |||
Charge current | 5.5A | |||
Interface | ||||
Alarm silence | YES | |||
DC power turn-on | YES | |||
Automatically retransfer | YES | |||
Audio alarm | ||||
Battery mode | Beep/4s | |||
Battery low/charger fault | Beep/1s | |||
UPS fault | Continue beep | |||
Overload | Beep/1s | |||
Bypass mode | Beep/2Min | |||
L/N inverse | Beep/2Min | |||
Communication | ||||
RS232 interface | YES | |||
Intelligent slot | YES | |||
Monitor software | Appending with UPS | |||
Cooling | ||||
Force air cooling | ||||
Display | ||||
LCD/LED displays UPS status | ||||
Environment | ||||
Work temperature | 0℃~40℃ | |||
Altitude | <1000m | |||
Audible noise | ≤60dB | ≤65dB | ||
Storage temperature | (-15℃~45℃) | |||
Work humidity | 20%~95% | |||
Standard | ||||
EMS | ||||
ESD | IEC61000-4-2 | Level4 | ||
RS | IEC61000-4-3 | Level3 | ||
EFT | IEC61000-4-4 | Level4 | ||
Surge | IEC61000-4-5 | Level4 | ||
EMI | ||||
Conducted | EN55022 | Class B | ||
Radiated | EN55022 | Class B | ||
Safety | ||||
Safety | GB4943-2001/IEC62040-1 | |||
Transportation | ||||
Drop test | GB-T4857-18 | |||
Vibration test | B-WR1-129(GB-T14715-93) | |||
Machinery features | ||||
Size | ||||
Outline dimension and net weight | ||||
length * width * height (mm) | 533*260*501 | 560*260*717 | ||
Net weight(Kg) | 24 | 39.5 | ||
Optional functions | ||||
60Hz | Set by software | |||
Converter mode | Set by software | |||
ECO | Optional | Available and set by software | ||
EPO | Optional | |||
LCD display | Optional |
Contact Person: Mr. Song
Tel: 86-137367899
Fax: 86-755-7287468
Single Phase / Three Phase Power Supply Online UPS for Communication System
Intelligent AC to DC Integrated Power Supply Online UPS High Frequency and Single Phase
Custom Three Phase Online UPS / 3 phase UPS Low Frequency for Network or Highway lighting
china Solar LED Street Light manufacturer
Solar Powered Street Lights 50 Watt | Integrated Series
IP 65 3000K 4000K Solar LED Street Lights Photovoltaic , Bright Solar Lights
High Power Low Frequency Online UPS IP20 DSP Control For Industrial
Low Frequency Online UPS With Touch Screen Function 10-200KVA
3Phase Low Frequency Online UPS With Isolation Transformer Inside