Product Details:
Payment & Shipping Terms:
|
Type: | High Frequency Online UPS | Phase: | Three Phase |
---|---|---|---|
Wave Form: | Pure Sine Wave | Cabinet: | Metal |
Highlight: | industrial ups systems |
High Frequency Online UPS Queen Star Plus Strar Series 33Q10K-80K(3Ph in/3Ph out)
Key Features
1: Generator compatible
2: Accepts dual power inputs
3: Perfect battery charge management.
4: Adopt 4 layers PCB, and SMD technology
5:Active input power factor correction(PFC)
6: SNMP+USB+RS-232 multiple communications
7: Alarm High-low Battery Input Voltage Protection Function
8: Environment Friendly and Energy Saving Technology Know-How
9: 3-stage extendable charging design for optimized battery performance
10:Advanced automatic constant charging circuit, prolongs battery life
11:Perfect protection against battery under voltage, overload and short circuit.
12:Auto restart after utility power restore when UPS shutdown due to battery low
Applications;
Alarm System, Building Automation System BAS, weak electricity system integration, CTP, PLC (Programmable Logic Controller), DDC (Direct Digital Control System), Data Center, manufacture industry, petrochemical system, metallurgical industry etc.
Technical Specification: | |||||||
Index | 33Q 10KL | 33Q 20KL | 33Q 30KL | 33Q 40KL | 33Q 60KL | 33Q 80KL | Comments |
Input | |||||||
Input voltage | |||||||
Rated voltage | 380VAC/220VAC | 380VAC | |||||
Phase | three phase with ground | ||||||
Turn on voltage range |
(120±5~274±5)VAC | (207±9~475±9) VAC |
|||||
Bypass voltage range |
(60±5~300±5)VAC | (105±9~518±9) VAC |
Could be adjusted by software. |
||||
Bypass low loss |
60VAC~220VAC(default 60VAC) | 105VAC~380VAC (default 105VAC) |
|||||
Bypass low comeback |
Low loss +5VAC | Low loss +17VAC |
|||||
Bypass high loss |
220VAC~300VAC(default 300VAC) | 380VAC~475VAC (default 475VAC) |
|||||
Bypass high comeback |
High loss -5VAC | High loss -17VAC | |||||
Line low loss comeback |
(120±5) VAC /(140±5) VAC | (207±9) VAC (242±9) VAC |
load≤50% | ||||
(140±5) VAC /(160±5) VAC | (242±9) VAC (276±9) VAC |
50%≤90% | |||||
(160±5) VAC /(175±5) VAC | (276±9) VAC (302±9) VAC |
load>90% | |||||
Line high loss comeback |
(275±5)VAC/(260±5)VAC | (475±9)VAC (449±9)VAC |
|||||
Input frequency | |||||||
Rated frequency |
50Hz | ||||||
Frequency low loss |
(40~49) ±0.2Hz(default:46Hz) | Could be adjusted by software. |
|||||
Frequency low comeback |
Frequency low loss +0.5Hz | ||||||
Frequency high loss |
(51~60)±0.2Hz(default:54Hz) | ||||||
Frequency high comeback |
Frequency high loss -0.5Hz | ||||||
Input power factor | |||||||
Could be adjusted by software. |
> 0.99 | 33Q 10-40KL: 220VAC,full R load 33Q 60-80KL: 380VAC,full R load |
|||||
Generator | Support generator input | Generator rating ≥2*UPS rating |
|||||
Input current | |||||||
Rated current | 14A | 28A | 42A | 67A | 80A | 105A | |
Input THDI | <= 10% | ||||||
Output protection | |||||||
Rating protection |
32A Breaker |
50A Breaker |
60A Breaker |
80A Breaker |
100A Breaker |
125A Breaker |
|
Output power | |||||||
VA/watt | 10KVA/8KW | 20KVA/16KW | 30KVA/24KW | 40KVA/32KW | 60KVA/ 48KW |
80KVA/ 64KW |
|
Rated voltage | 220VAC | 380VAC | Sine wave | ||||
Voltage range | 200/208/220 /230/240VAC |
345/359/380 /397/415 VAC |
33Q 10-40KL: Could be adjusted by software. 10% derating for 208VAC /200VAC. 33Q 60-80KL: Could be adjusted by software. 10% derating for 345VAC /359VAC. |
||||
Voltage regulation | ±1% | ||||||
Voltage distortion | ≤5% | ≤10% | Full RCD load | ||||
≤3% | Full R load | ||||||
DC offset | ≤200mV | ||||||
Transient response | ≤9% | R load 0%~100%~0% |
|||||
≤6% | R load 20% ~100%~20% |
||||||
Transient recovery | ≤60ms voltage recovery to 90% | Full RCD load | |||||
Bypass output before turn-on |
YES | ||||||
Crest ration | 3:1 | ||||||
Output frequency range | |||||||
Normal mode | 1,Same as input frequency(46Hz~54Hz) 2,50Hz(Input frequency>54Hz or Input frequency<46Hz) |
||||||
Battery mode | (50±0.1) Hz | ||||||
Slew rate | 1 Hz/Sec | ||||||
Efficiency | |||||||
Normal mode | > 93% | > 90% | |||||
Battery mode | > 90% | > 90% | |||||
Overload | |||||||
Normal mode battery mode |
Overload warning only | 105%±5%≤load | |||||
1min,then transfer to bypass and alarm. | 105%±5%< load≤125%±5% |
||||||
30S,then transfer to bypass and alarm. | 125%±5%< load≤150%±5% |
||||||
300mS, then transfer to bypass and alarm. | load>150%±5% | ||||||
Automatically retransfer |
YES | ||||||
Short protection | |||||||
Normal battery mode |
YES | ||||||
Transfer time | |||||||
Normal to battery mode |
0mS | ||||||
Battery to normal mode |
0mS | ||||||
Normal to bypass mode |
<4mS | 0mS | |||||
Bypass to normal mode |
<4mS | 0mS | |||||
Battery and charger | |||||||
Battery | |||||||
Rated voltage | 192VDC | 240VDC | 192VDC*2 | 192VDC*2 | 480VDC | ||
Type/Rating | |||||||
Battery quantity |
16 | 20 | 16*2 | 16*2 | 40 | ||
Backup time | |||||||
Protection | |||||||
Low alarm voltage comeback voltage |
(180.8V±4V)/ (188.8V±4V) | (226V±4V)/ (236V±4V) | (180.8V±4V) (188.8V±4V) |
(226V±4V)/ (236V±4V) | (452V±4V) (472V±4V) |
33Q 30KL use two |
|
Shutdown voltage comeback voltage |
160V±4V/ 168V±4V |
(200V±4V)/ (210V±4V) | 160V±4V/ 168V±4V |
(200V±4V)/ (210V±4V) | (400V±4V) (420V±4V) |
||
DC protection | |||||||
Overcharge protection comeback voltage |
(249.6V±4V) (216V±4V) |
(312V±4V) (270V±4V) | (249.6V±4V) (216V±4V) |
(312V±4V) (270V±4V) | (624V±4V) (540V±4V) |
||
Leakage current | < 500uA | ||||||
Over discharge protection |
14.5h | Could be set by software |
|||||
Battery test | |||||||
Battery weak | YES | ||||||
Battery fault | YES | ||||||
Charger | |||||||
Output voltage | (219.2±3)VDC | (277±3)VDC | (219.2±3)VDC | (277±3)VDC | (554±3)VDC | ||
Charge time | Depends on the external battery capacity | ||||||
Charge current | 7.5A | 6A | 5A | 4A | 10A | ||
Interface | |||||||
Alarm silence | YES | ||||||
DC power turn-on |
YES | ||||||
Automatically retransfer |
YES | ||||||
Audio alarm | |||||||
Battery mode | Beep/4s | ||||||
Battery low charger fault |
Beep/1s | ||||||
UPS fault | Continue beep | ||||||
Overload | Beep/1s | ||||||
Bypass mode | Beep/2Min | ||||||
L/N inverse | Beep/2Min | ||||||
Communication | |||||||
RS232 interface | YES | ||||||
Intelligent slot | YES | ||||||
Monitor software | Appending with UPS | ||||||
Cooling | |||||||
Force air cooling | |||||||
Display | |||||||
LCD/LED displays UPS status | |||||||
Environment | |||||||
Work temperature |
0ºC~40ºC | ||||||
Altitude | <1000m | ||||||
Audible noise |
≤60dB | ||||||
Storage temperature |
-15ºC~45ºC | ||||||
Work humidity | 20%~95% | ||||||
Standard | |||||||
EMS | |||||||
ESD | IEC61000-4-2 | Level4 | |||||
RS | IEC61000-4-3 | Level3 | |||||
EFT | IEC61000-4-4 | Level4 | |||||
Surge | IEC61000-4-5 | Level4 | |||||
EMI | |||||||
Conducted | EN55022 | Class A | |||||
Radiated | EN55022 | Class A | |||||
Safety | |||||||
Safety | GB4943-2001/IEC62040-1 | ||||||
Machinery features | |||||||
Size | |||||||
Outline dimension and net weight | |||||||
L*W*H (mm) | 710*260*717 | 840*515*1135 | |||||
Net weight(Kg) | 45/93 | 50/98 | 195 | 208 | |||
Optional functions | |||||||
60Hz | Optional | Set by software | |||||
Converter mode | Optional | Set by software | |||||
ECO | Optional | Optional | Available and set by software |
||||
EPO | Optional | Optional | |||||
LCD display | Optional |
Contact Person: Mr. Song
Tel: 86-137367899
Fax: 86-755-7287468
Single Phase / Three Phase Power Supply Online UPS for Communication System
Intelligent AC to DC Integrated Power Supply Online UPS High Frequency and Single Phase
Custom Three Phase Online UPS / 3 phase UPS Low Frequency for Network or Highway lighting
china Solar LED Street Light manufacturer
Solar Powered Street Lights 50 Watt | Integrated Series
IP 65 3000K 4000K Solar LED Street Lights Photovoltaic , Bright Solar Lights
High Power Low Frequency Online UPS IP20 DSP Control For Industrial
Low Frequency Online UPS With Touch Screen Function 10-200KVA
3Phase Low Frequency Online UPS With Isolation Transformer Inside