Product Details:
Payment & Shipping Terms:
|
Highlight: | Single Phase UPS |
---|
1 Phase In And Out Online UPS 110VAC-288VAC Wide Input Range
Quick Detail:
Specifications:
Model | HT1101L | HT1101S | HT1102L | HT1102S | HT1103L | HT1103S |
INPUT | ||||||
Cold Start | YES, default frequency=50Hz or settable | |||||
Acceptable Input Voltage | 110VAC~288VAC | |||||
100% load@>176VAC | ||||||
80% load@>154VAC | ||||||
70% load@>132VAC | ||||||
50% load@>110VAC | ||||||
Phase | Single phase in,single phase out | |||||
Transfer Voltage Range | (200VAC/208VAC/220VAC/230VAC/240VAC) | |||||
Line low transfer | 110VAC | |||||
Line low recovery | 121VAC | |||||
Line high transfer | 288VAC | |||||
Line high recovery | 281VAC | |||||
Input Current | ||||||
Rating(nominal input voltage) | 4.8A | 9.6A | 14.4A | |||
Input Power Factor | ≥0.97 | |||||
Input Frequency Range | 40~70Hz | |||||
Output | ||||||
Frequency adaptable | Settable | |||||
Power | ||||||
Power(kVA) max | 1 | 2 | 3 | |||
Power(kW) max | 0.9 | 1.8 | 2.7 | |||
Output Voltage | ||||||
Waveform(Bat. Mode) | Pure Sine Wave | |||||
Nominal voltage | 200/208/220/230/240VAC | |||||
Voltage regulation | ± 1 % | |||||
Transient response | ≤5% (0% - 100% -0%) | |||||
Transient recovery | ≤10ms (0% - 100% -0%) | |||||
Voltage distortion | ≤1% THD, linear load | |||||
≤ 5.5% THD, non-linear load | ≤ 5% THD, non-linear load | ≤ 5% THD, non-linear load | ||||
Output Frequency | ||||||
Synonization range | ±5Hz default | |||||
Slew rate | 0.5~5Hz/s,2 Hz/s default | |||||
Battery mode | (50±0.1) Hz | |||||
Transfer Time | ||||||
Line mode to battery mode | 0 | |||||
Inverter to bypass | 2ms | |||||
Efficiency | ||||||
Line mode with battery full ged | 86.0% | 89.0% | 89.0% | |||
ECO mode | 98.0% | 98.0% | 98.0% | |||
Battery mode | 83.0% | 87.0% | 87.0% | |||
Noise(1m away) | <43dB@<70%load,<50dB@>70%load | <45dB@<70%load,<50dB@>70%load | <45dB@<70%load,<50dB@>70%load | |||
Overload Capability(Inverter) | 105%~130%: Transfer to bypass after 1 mins. | |||||
150%: Transfer to bypass after 30s | ||||||
Overload Capability (Battery Mode) |
105%~130%:shutdown after 10s | |||||
150%:shutdown after 5s | ||||||
Overload Capability (Bypass Mode) | <130%: Long time | |||||
>130%&<150%:Shutdown after 10min | ||||||
>150%&<180%:Shutdown after 5 seconds | ||||||
Crest Ratio | 3:1 | |||||
Battery | ||||||
Rating/Type | 12VDC/7Ah | 12VDC/7Ah | 12VDC/7Ah | |||
Quantity | 3 | 6 | 8 | |||
DC Voltage | 36VDC | 72VDC | 96VDC | |||
Back-up Time | 6mins @80% load | Depend on external batteries | 6mins @80% load | Depend on external batteries | 5.5mins @80% load | Depend on external batteries |
Battery-Low Voltage | 33VAC~35VDC depending on load | 66VDC~70VDC depending on load | 88VDC~94VDC depending on load | |||
Charger | ||||||
Charging voltage | float:41VDC/boost:42VDC | float:82VDC/boost:84VDC | float:109VDC/boost:112VDC | |||
Charging current (max) | 1A | 8A | 1A | 8A | 1A | 8A |
Charging time | 8h rege to 90% | Depend on the capacity of external batteries | 8h rege to 90% | Depend on the capacity of external batteries | 8h rege to 90% | Depend on the capacity of external batteries |
Leakage current | <1mA | <1mA | <1mA | |||
Indicator & Alarm | ||||||
Display | LED+LCD | |||||
Alarm | two short one long | |||||
Fault | Continuous beeping | |||||
Interface | ||||||
Smart RS232 | Standard Cable support INVT Power Monitor Software | |||||
SNMP(option) | Power Managment from SNMP Manager and Web Browser | |||||
Option | ||||||
Intelligent Kits | pluggable type,DB9 | |||||
Intelligent Kits | non-pluggable type,DB9 | |||||
SNMP Kits | pluggable type | |||||
Mechanical | ||||||
W╳D╳H (mm) | 144*353*222 | 190*374*336 | 190*426*336 | |||
Net Weight (KG) | 6 | 12 | 21 | 10 | 26 | 11 |
Package Weight(KG) | 7 | 13 | 22 | 11 | 27 | 12 |
Color | Black default |
Applications:
Contact Person: Mr. Song
Tel: 86-137367899
Fax: 86-755-7287468
Single Phase / Three Phase Power Supply Online UPS for Communication System
Intelligent AC to DC Integrated Power Supply Online UPS High Frequency and Single Phase
Custom Three Phase Online UPS / 3 phase UPS Low Frequency for Network or Highway lighting
china Solar LED Street Light manufacturer
Solar Powered Street Lights 50 Watt | Integrated Series
IP 65 3000K 4000K Solar LED Street Lights Photovoltaic , Bright Solar Lights
High Power Low Frequency Online UPS IP20 DSP Control For Industrial
Low Frequency Online UPS With Touch Screen Function 10-200KVA
3Phase Low Frequency Online UPS With Isolation Transformer Inside